Dosimeters, radiometers
SAFETY,
RELIABILITY,
SIMPLICITY.
city  (044) 393-39-93
MTC  ---------------------
KievStar  ---------------------
info@doza.net.ua
 main        payment        delivery        service        contacts        articles        accessories
УкраїнськоюРусский


 Dosimeter of gamma-radiation DKG-AT2140

DKG-AT2140

Price:
10200 UAH
Available:
yes

DKG-AT2140 kit

Dosimeter is intended for measuring ionizing radiation including dose rate of gamma-radiation and accumulated dose. Additionally the functions of illuminating of display are realized in a dosimeter. In the dosimeter values of threshold levels of dose and dose rate are programmed. Dosimeter beeps (can be disabled) in excess of the threshold. The device shows low battery and level of current measurement error (<15%, <25% or <50%).

A dosimeter (and it modifications) can be used wide around users (by the personnel of industrial enterprises, radiological laboratories, by the employees of emergency services, population) for control of radiation cleanness of dwellings apartments, buildings and premises, objects, transport vehicles, building materials, surface of soil, money signs etc. This dosimeter is a subject for decontamination.

Dosimeter is a compact device with high sensitivity (due to the presence of two detectors instead of one), and having a minimum of necessary functions for measuring radiation. In the case of the official measuring a dosimeter is subject a periodic check with frequency of at least 1 time per year.

Parameter
-
Value
Detector type / (quantity)
-
Geiger tube
/ (2)
Measurement of equivalent dose rate (EDR) of gamma-radiation
gamma-radiation
0,1 mkSv/h - 10 mSv/h
Measurement error for EDR of gamma-radiation
-
±15 and more
Measurement of accumulated equivalent dose (ED) of gamma-radiation
accumulated dose
0,1 mkSv - 1,99 Sv
Measurement error for ED of gamma-radiation
-
±15 and more
Registered energies of gamma-radiation
-
50 keV - 3,0 MeV
Flux density of beta-particles
-
-
Measure error for flux density of beta-particles
-
-
Registered energies of beta-radiation
-
-
Range of working temperatures
-
-20...+50°C
Index of protection
waterproof
Time of work from one set of batteries
-
5000 hours
Type (number) of battery
-
AA (2)
Build-in memory
-
-
Communication with PC
-
-
Additional functions
-
-
Overall sizes
-
111x70x28 mm
Weight
-
110 g
Estimated period of service
-
20000 hours
Guarantee term of exploitation
-
18 month
Sertification (periodic check)
state calibration
yes (12 month)
Producer
-
Byelorus

BACK ON DOSIMETERS SELECTION PAGE